Aeon Labs Energy Meter
http://www.aeon-labs.com/site/products/view/4/
Aeon Labs Energy Meter
The Aeon Labs Smart Energy Monitor is a low-cost energy monitor for the entire home. It can wirelessly report immediate wattage and kWh usage to central control point gateways such as the 4HomeMedia CP and can be easily and safely installed by anyone.
Ease and safety are paramount: Electricians are not required to install the Aeon Labs Smart Energy Monitor; the customer never needs to handle hot exposed wiring. Current transformer clamps clamp around the AC Mains to detect energy usage for the entire house. The main body is anchored using a back mount which opens to easily for battery replacement every 1 years.
Contents
Configuration
Parameter Number Definitions(8 bit)
Parameter 1
Voltage to calculate wattage from amperage. Values represent voltage.
Defaults:
120(country:US) 240(country:EU,ANZ)
Size: 2
Parameter 20
This byte denotes whether the product is using batteries (value == 0) or using USB power (value == 1).
Size: 1
Parameter 100
Reset to default parameters number 101-103. Any value other than 0 will initiate this reset.
Size: 4
Parameter 101
Which reports need to send in group1
Size: 4
Parameter 102
Which reports need to send in group2
Size: 4
Parameter 103
Which reports need to send in group3
Size: 4
Parameter 110
Reset to default parameters number 111-113. Any value other than 0 will initiate this reset.
Size: 4
Parameter 111
The interval of sending report group 1(seconds) Default:
720
Size: 4
Parameter 112
The interval of sending report group 2(seconds) Default:
720
Size: 4
Parameter 113
The interval of sending report group 3(seconds) Default:
720
Size: 4
Parameter 255
Reset to the default Configuration
Size: 4
Configuration Flags for parameters 101-103
Bytes 1-3 are reserved
Byte 4 (LSB):
Bit 2: Send Meter REPORT (for wattage) at the group time interval
Bit 1: Send Multilevel Sensor REPORT (for wattage) at the group time interval
Bit 0: Send Battery REPORT at the group time interval