Difference between revisions of "Bash dce knx"

From LinuxMCE
Jump to: navigation, search
(New page: 1. Install the packages; 2. Go into the pluto-admin website, in Interfaces, and add a EIB device Edit the EIB device template, and make the command line field say KNX.sh Set the serial...)
 
Line 1: Line 1:
 
 
1. Install the packages;
 
1. Install the packages;
  
 
+
http://diapub.com/files/bash-dce-knx.tgz
  
 
2. Go into the pluto-admin website, in Interfaces, and add a EIB device
 
2. Go into the pluto-admin website, in Interfaces, and add a EIB device

Revision as of 13:35, 16 September 2008

1. Install the packages;

http://diapub.com/files/bash-dce-knx.tgz

2. Go into the pluto-admin website, in Interfaces, and add a EIB device Edit the EIB device template, and make the command line field say KNX.sh Set the serial port to the corresponding USB port (last time there was just one serial usb adaptor: that of the SIM-KNX device).

3. Go in Lights, add a on/off light. Set its room. Write "$00 $03" (w/o the quotes) in the "Port/Channel number" Device Data

4. Go in Climate, add a Generic Thermostat. Set its room. Write "$$ $32" (double dollar sign is correct, w/o the quotes) in the "Port/Channel number" Device Data

5. Setup the floorplans.

6. Reboot, (regen?) and it should work.