Difference between revisions of "Danfoss Living-Connect"
From LinuxMCE
(Created page with "36 01/31/12 15:25:25.964 FUNC_ID_ZW_APPLICATION_UPDATE:UPDATE_STATE_NODE_INFO_RECEIVED received from node 44 - <0x7fc7aa0aa700> 36 01/31/12 15:25:25.964 ...") |
(→Command Classes) |
||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | 36 01/31/12 15:25:25.964 FUNC_ID_ZW_APPLICATION_UPDATE:UPDATE_STATE_NODE_INFO_RECEIVED received from node 44 - <0x7fc7aa0aa700> | + | [[Category: Hardware]] |
− | 36 01/31/12 15:25:25.964 Running wakeupHandler for node 44 <0x7fc7aa0aa700> | + | [[Category: Automation]] |
− | 36 01/31/12 15:25:25.964 Moving job 0x1f2ccf0 from wakup to send queue <0x7fc7aa0aa700> | + | [[Category: Climate]] |
− | 36 01/31/12 15:25:25.964 Supported command classes: <0x7fc7aa0aa700> | + | [[Category: ZWave]] |
− | 36 01/31/12 15:25:25.964 COMMAND_CLASS_BATTERY <0x7fc7aa0aa700> | + | [[Category: ZWave_radiator_thermostat]] |
− | 36 01/31/12 15:25:25.965 COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULE <0x7fc7aa0aa700> | + | {{versioninfo}} |
− | 36 01/31/12 15:25:25.965 COMMAND_CLASS_CLOCK <0x7fc7aa0aa700> | + | [[Image:Danfoss_Living-Connect.jpg|thumb|200px|Danfoss RA-PLUS-w ZWave radiator thermostat]] |
− | 36 01/31/12 15:25:25.965 COMMAND_CLASS_MANUFACTURER_PROPRIETARY <0x7fc7aa0aa700> | + | |
− | 36 01/31/12 15:25:25.965 COMMAND_CLASS_MANUFACTURER_SPECIFIC <0x7fc7aa0aa700> | + | = Status = |
− | 36 01/31/12 15:25:25.965 COMMAND_CLASS_MULTI_CMD <0x7fc7aa0aa700> | + | unknown |
− | 36 01/31/12 15:25:25.965 COMMAND_CLASS_PROTECTION <0x7fc7aa0aa700> | + | |
− | 36 01/31/12 15:25:25.965 COMMAND_CLASS_THERMOSTAT_SETPOINT <0x7fc7aa0aa700> | + | = About = |
− | 36 01/31/12 15:25:25.965 COMMAND_CLASS_VERSION <0x7fc7aa0aa700> | + | Radiator Thermostat, successor of the RA-Plus-W |
− | 36 01/31/12 15:25:25.965 COMMAND_CLASS_WAKE_UP <0x7fc7aa0aa700> | + | |
− | 36 01/31/12 15:25:25.965 * COMMAND_CLASS_MARK * <0x7fc7aa0aa700> | + | = Device setup = |
− | 36 01/31/12 15:25:25.965 Can control the following command classes: <0x7fc7aa0aa700> | + | == General information == |
− | 36 01/31/12 15:25:25.965 COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULE <0x7fc7aa0aa700> | + | |
− | 36 01/31/12 15:25:25.965 COMMAND_CLASS_CLOCK <0x7fc7aa0aa700> | + | == Reset unit == |
− | 36 01/31/12 15:25:25.965 COMMAND_CLASS_MANUFACTURER_PROPRIETARY <0x7fc7aa0aa700> | + | Remove Batteries, press and hod the "o" Button, insert batteries, wait 5 seconds, release button |
− | 36 01/31/12 15:25:25.965 COMMAND_CLASS_MULTI_CMD <0x7fc7aa0aa700> | + | |
+ | = Command Classes = | ||
+ | 36 01/31/12 15:25:25.964 FUNC_ID_ZW_APPLICATION_UPDATE:UPDATE_STATE_NODE_INFO_RECEIVED received from node 44 - <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.964 Running wakeupHandler for node 44 <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.964 Moving job 0x1f2ccf0 from wakup to send queue <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.964 Supported command classes: <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.964 COMMAND_CLASS_BATTERY <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULE <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 COMMAND_CLASS_CLOCK <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 COMMAND_CLASS_MANUFACTURER_PROPRIETARY <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 COMMAND_CLASS_MANUFACTURER_SPECIFIC <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 COMMAND_CLASS_MULTI_CMD <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 COMMAND_CLASS_PROTECTION <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 COMMAND_CLASS_THERMOSTAT_SETPOINT <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 COMMAND_CLASS_VERSION <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 COMMAND_CLASS_WAKE_UP <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 * COMMAND_CLASS_MARK * <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 Can control the following command classes: <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULE <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 COMMAND_CLASS_CLOCK <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 COMMAND_CLASS_MANUFACTURER_PROPRIETARY <0x7fc7aa0aa700> | ||
+ | 36 01/31/12 15:25:25.965 COMMAND_CLASS_MULTI_CMD <0x7fc7aa0aa700> | ||
+ | = Manufacturer = | ||
+ | |||
+ | 36 01/31/12 15:40:33.296 REPORT: Manuf: 0x5254, Prod Typ: 0x100, Prod 0x8375 <0x7fc7aa0aa700> |
Latest revision as of 15:41, 31 January 2012
Version | Status | Date Updated | Updated By |
---|---|---|---|
710 | Unknown | N/A | N/A |
810 | Unknown | N/A | N/A |
1004 | Unknown | N/A | N/A |
1204 | Unknown | N/A | N/A |
1404 | Unknown | N/A | N/A |
Usage Information |
Contents
Status
unknown
About
Radiator Thermostat, successor of the RA-Plus-W
Device setup
General information
Reset unit
Remove Batteries, press and hod the "o" Button, insert batteries, wait 5 seconds, release button
Command Classes
36 01/31/12 15:25:25.964 FUNC_ID_ZW_APPLICATION_UPDATE:UPDATE_STATE_NODE_INFO_RECEIVED received from node 44 - <0x7fc7aa0aa700> 36 01/31/12 15:25:25.964 Running wakeupHandler for node 44 <0x7fc7aa0aa700> 36 01/31/12 15:25:25.964 Moving job 0x1f2ccf0 from wakup to send queue <0x7fc7aa0aa700> 36 01/31/12 15:25:25.964 Supported command classes: <0x7fc7aa0aa700> 36 01/31/12 15:25:25.964 COMMAND_CLASS_BATTERY <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULE <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 COMMAND_CLASS_CLOCK <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 COMMAND_CLASS_MANUFACTURER_PROPRIETARY <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 COMMAND_CLASS_MANUFACTURER_SPECIFIC <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 COMMAND_CLASS_MULTI_CMD <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 COMMAND_CLASS_PROTECTION <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 COMMAND_CLASS_THERMOSTAT_SETPOINT <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 COMMAND_CLASS_VERSION <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 COMMAND_CLASS_WAKE_UP <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 * COMMAND_CLASS_MARK * <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 Can control the following command classes: <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULE <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 COMMAND_CLASS_CLOCK <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 COMMAND_CLASS_MANUFACTURER_PROPRIETARY <0x7fc7aa0aa700> 36 01/31/12 15:25:25.965 COMMAND_CLASS_MULTI_CMD <0x7fc7aa0aa700>
Manufacturer
36 01/31/12 15:40:33.296 REPORT: Manuf: 0x5254, Prod Typ: 0x100, Prod 0x8375 <0x7fc7aa0aa700>