Difference between revisions of "Seluxit viaSENS Home Controller"
m |
(→Setup) |
||
(17 intermediate revisions by 8 users not shown) | |||
Line 1: | Line 1: | ||
[[Category: Hardware]] | [[Category: Hardware]] | ||
[[Category: Automation]] | [[Category: Automation]] | ||
+ | [[Category: RF Control]] | ||
[[Category: ZWave]] | [[Category: ZWave]] | ||
+ | [[Category: ZWave_controller]] | ||
− | [[Image: | + | {{versioninfo|810Status=PnP|810UpdatedDate=12th May 2010|810UpdatedBy=sambuca}} |
+ | [[Image:VSHomeController.jpg|thumb|200px|Seluxit viaSENS Homecontroller]] | ||
= Status = | = Status = | ||
− | + | Received sample from manufacturer. Plug and play with versions >= 0710b4. | |
+ | |||
+ | This is the _recommended_ interface for Europe. | ||
= About = | = About = | ||
− | The Seluxit viaSENS Homecontroller is a USB Z-Wave Controller based on a Zensys chip | + | The Seluxit viaSENS Homecontroller is a USB Z-Wave Controller based on a Zensys chip. It uses a frequency of 868MHz. |
+ | |||
+ | = Setup = | ||
+ | To setup this device using SIS mode, send it a Reset command. In the web admin, go to Advanced -> Devices, find the ZWave device in the tree, select it, click "Send Command To Device" in the right pane. Select "Reset", enter "ResetController" in the Arguments field, and click Send Command. Note: This will delete all ZWave devices from your network. | ||
+ | Now the device will get node id 1, and SIS mode is enabled, which means that LMCE assigns new node ids to added nodes. | ||
+ | |||
+ | New nodes(Z-Wave devices) can be added by sending the ZWave device a "Add Node" command. Follow the description above, only use Add Node instead of Reset. No parameters are necessary, but you could try using H for high power if you have problems adding a node. | ||
+ | |||
+ | = USB = | ||
+ | ID: 16c0:06eb | ||
+ | Driver: cdc_acm | ||
= Links = | = Links = | ||
− | http://www.seluxit.com/ | + | http://www.seluxit.com/products/devices/ |
+ | http://www.hightechpad.com/?q=content/seluxit-z-wave-usb-controller |
Latest revision as of 21:51, 25 April 2014
Version | Status | Date Updated | Updated By |
---|---|---|---|
710 | Unknown | N/A | N/A |
810 | PnP | 12th May 2010 | sambuca |
1004 | Unknown | N/A | N/A |
1204 | Unknown | N/A | N/A |
1404 | Unknown | N/A | N/A |
Usage Information |
Status
Received sample from manufacturer. Plug and play with versions >= 0710b4.
This is the _recommended_ interface for Europe.
About
The Seluxit viaSENS Homecontroller is a USB Z-Wave Controller based on a Zensys chip. It uses a frequency of 868MHz.
Setup
To setup this device using SIS mode, send it a Reset command. In the web admin, go to Advanced -> Devices, find the ZWave device in the tree, select it, click "Send Command To Device" in the right pane. Select "Reset", enter "ResetController" in the Arguments field, and click Send Command. Note: This will delete all ZWave devices from your network. Now the device will get node id 1, and SIS mode is enabled, which means that LMCE assigns new node ids to added nodes.
New nodes(Z-Wave devices) can be added by sending the ZWave device a "Add Node" command. Follow the description above, only use Add Node instead of Reset. No parameters are necessary, but you could try using H for high power if you have problems adding a node.
USB
ID: 16c0:06eb Driver: cdc_acm
Links
http://www.seluxit.com/products/devices/ http://www.hightechpad.com/?q=content/seluxit-z-wave-usb-controller