Difference between revisions of "Express Controls EZmotion (HSM 100)"

From LinuxMCE
Jump to: navigation, search
(Configuration)
(Configuration)
Line 55: Line 55:
 
By default it seems that the HSM 100 has a motion timeout of 20 minutes. That means that it will not send any motion detection events for 20 minutes after it is first tripped. This is a useful setting for saving batteries but not a useful setting for an occupancy sensor controlling lights. To set the motion timeout of the HSM 100:
 
By default it seems that the HSM 100 has a motion timeout of 20 minutes. That means that it will not send any motion detection events for 20 minutes after it is first tripped. This is a useful setting for saving batteries but not a useful setting for an occupancy sensor controlling lights. To set the motion timeout of the HSM 100:
  
Select the ZWave device in the advanced web config devices section
+
#Select the ZWave device in the advanced web config devices section.
Select send command to device
+
#Select send command to device.
Select "Set Config Param" as the command to send
+
#Select "Set Config Param" as the command to send.
 
#48 Value (int) = Your desired timeout in minutes
 
#48 Value (int) = Your desired timeout in minutes
 
#239 NodeID (int) = The ZWave node ID of the HSM 100 to configure
 
#239 NodeID (int) = The ZWave node ID of the HSM 100 to configure
 
#248 Parameter ID (int) = 2
 
#248 Parameter ID (int) = 2
 
+
#Press the blue button on the side of the HSM 100 you are trying to configure
Press the blue button on the side of the HSM 100 you are trying to configure before you click "Send Message"
+
#Click "Send Message"
  
 
= Command classes =
 
= Command classes =

Revision as of 23:59, 6 November 2010

Version Status Date Updated Updated By
710 Unknown N/A N/A
810 Working,PnP as 3 multilevel sensors 4th May 2010 sambuca
1004 Unknown N/A N/A
1204 Unknown N/A N/A
1404 Unknown N/A N/A
Usage Information

About

The EZMotion is a 3-in-1 Z-Wave sensor. This is also sold by Innovus and Homeseer (HSM100)

Manuf ID1: 0x0 ID2: 0x1e, Prod Typ1: 0x0 Typ2: 0x2, Prod ID1: 0x0 ID2: 0x1

Features

  • Motion detection
  • Light sensor
  • Temperature sensor.

Setup

If you use SIS mode in your ZWave setup, this device should automatically be added as three multilevel sensors. If not, it is possible to set it up manually. If you are running SIS mode, you can delete the main device and re-add it as a motion detector, see below for details.

You will have one multilevel sensor added for the EZMotion. Find and open this from the device tree. We will change this to be the thermometer instance. Find the Port/Channel number. This is the node ID. Change the Port/Channel number to <node id>/3 (for instance 4/3 if your node id is 4), type to Thermometer, insert 49 in Capabilities, and save.

Add a new device below the ZWave Embedded Climate Interface using the same device template (Multilevel sensor). Insert <node id>/2 in Port/Channel number, insert 49 in Capabilities and save. This will be the brightness sensor. Please notice that the values returned from this sensor ranges from 0 to 100% and is relative to the light measured since X (see the manual).

Then we add the Motion detector. This will not be added automatically even when running the SIS mode. Open the ZWave Embedded Security Interface and click Create New Child. Select the Motion Detector template. Insert <node id> in Port/Channel number, Motion Detector in type, 133,96,49,112,132,128,114,119,134 in Capabilities, and save.

Reload router and you should receive events from all three sensors. The motion detector will also report a values(which is not sent to LMCE atm.). This value if the number of minutes since last motion was detected, and 0 if no motion was detected. See the manual for more information.

Configuration

To change the interval temperature and light is reported go to Home > My Devices > CORE > ZWave and chose "Send command to device". Select "SetWakeUp" and set parameters as follows:

48 Value (int) : <the time in minutes can only be 6 or any increment of 6>
239 NodeID (int) : <the zwave nodeid>

Send Message

Then push the button on the EZmotion (HSM 100)


By default it seems that the HSM 100 has a motion timeout of 20 minutes. That means that it will not send any motion detection events for 20 minutes after it is first tripped. This is a useful setting for saving batteries but not a useful setting for an occupancy sensor controlling lights. To set the motion timeout of the HSM 100:

  1. Select the ZWave device in the advanced web config devices section.
  2. Select send command to device.
  3. Select "Set Config Param" as the command to send.
  4. 48 Value (int) = Your desired timeout in minutes
  5. 239 NodeID (int) = The ZWave node ID of the HSM 100 to configure
  6. 248 Parameter ID (int) = 2
  7. Press the blue button on the side of the HSM 100 you are trying to configure
  8. Click "Send Message"

Command classes

0x4 0x21 0x1

  • COMMAND_CLASS_MULTI_INSTANCE
  • COMMAND_CLASS_SENSOR_MULTILEVEL
  • COMMAND_CLASS_CONFIGURATION
  • COMMAND_CLASS_WAKE_UP
  • COMMAND_CLASS_ASSOCIATION
  • COMMAND_CLASS_BATTERY
  • COMMAND_CLASS_MANUFACTURER_SPECIFIC
  • COMMAND_CLASS_NODE_NAMING
  • COMMAND_CLASS_VERSION

Links

http://www.expresscontrols.com

http://www.expresscontrols.com/pdf/EZMotionOwnerManual.pdf

Which type of AAA battery to use in EZMotion?