Difference between revisions of "InteractiveTechnologies CueServer-Pro-CS-800"
From LinuxMCE
m |
m (Added category: GSD) |
||
Line 1: | Line 1: | ||
[[Category: Automation]] [[Category: hardware]] | [[Category: Automation]] [[Category: hardware]] | ||
+ | [[Category: GSD]] | ||
This is a template for a DMX lighting controller by Interactive technologies - model [http://www.interactive-online.com/products/cueserver/overview Cueserver pro800] | This is a template for a DMX lighting controller by Interactive technologies - model [http://www.interactive-online.com/products/cueserver/overview Cueserver pro800] | ||
Its very basic at the moment however it is working using the serial port I have followed the guide in the wiki "Implementing Clipsal Interface using Generic Serial Device"also adding in device data #76 COM Port ParityBit/Stop(string) #78 COM Port BaudRate(string) | Its very basic at the moment however it is working using the serial port I have followed the guide in the wiki "Implementing Clipsal Interface using Generic Serial Device"also adding in device data #76 COM Port ParityBit/Stop(string) #78 COM Port BaudRate(string) |
Latest revision as of 15:51, 11 July 2016
This is a template for a DMX lighting controller by Interactive technologies - model Cueserver pro800 Its very basic at the moment however it is working using the serial port I have followed the guide in the wiki "Implementing Clipsal Interface using Generic Serial Device"also adding in device data #76 COM Port ParityBit/Stop(string) #78 COM Port BaudRate(string)
in the RUBY CODE under "Ruby Internal Commands"-"#384 Process Receive Command For Child "add
id=device_.childdevices_[cmd.devidto_].devdata_[12]#get child device number if cmd.id_==192 #192 is on conn_.Send("[c"+id+"atfl]\r") #set id to full end if cmd.id_==193 #193 is off conn_.Send("[c"+id+"rel]\r") #relase id to zero end if cmd.id_==184 #184 dimmer conn_.Send("[c"+id+"at50]\r") #set id to 50% it should step the light up or down this is not working at present end
Things To Do
- get #184 the dimmer command to work correctly
- add log/messages to keep lmce up to date
- intergrate the 8 contact closures on the cueserver this could work as alarm interface
- get it to work over the ethernet write a driver in c++