Difference between revisions of "Insteon PLM Ruby Code 776"

From LinuxMCE
Jump to: navigation, search
m
m (Added category: GSD)
 
Line 1: Line 1:
 
{{Versioninfo}}
 
{{Versioninfo}}
 
[[category: Insteon]]
 
[[category: Insteon]]
 +
[[Category: GSD]]
 
<pre>#### Written by Dan Damron
 
<pre>#### Written by Dan Damron
 
### #776 Reset
 
### #776 Reset

Latest revision as of 15:29, 7 July 2016

Version Status Date Updated Updated By
710 Unknown N/A N/A
810 Unknown N/A N/A
1004 Unknown N/A N/A
1204 Unknown N/A N/A
1404 Unknown N/A N/A
Usage Information
#### Written by Dan Damron
### #776 Reset
#First, Lets see if we actually 'get this command'
log($yellow+ '*#*#*#*#*#*#*#*# GOT #776 Reset! *#*#*#*#*#*#*#*#*'+ $grey)


myDevFrom = device_.devid_
myDevTo = -1001
myDevPriority = 1
myDevType = 2 #event
myDevID = 65 # Device Detected
#create command
cmd = Command.new(myDevFrom, myDevTo, myDevPriority, myDevType, myDevID)
#Add params...
cmd.params_[28] = '' #IP Address
cmd.params_[5] = '' #MAC Address
cmd.params_[56] = "73" # environment - Lighting Device
cmd.params_[49] = "38" # Light (dimmable) PK_DeviceTemplate
#PK_FloorplanObjectType of 10 is Table Lamp, 9 is ceiling light
#PK_FloorplanObjectType is devicedata #11
#0a.97.0b is test lamp
#0b.71.ab is Office Light
cmd.params_[55] = "11|10|12|0A.97.0B" # test lamp module PK_DeviceData
cmd.params_[13] = "SwitchLinc V2" # text to display
cmd.params_[51] = "0A.97.0B" # VendorModelID
cmd.params_[52] = "11" # PK_CommMethod
cmd.params_[53] = "2" #PK_PnpProtocol
cmd.params_[54] = "0A.97.0B[54]" #PNP_Serial_Number
cmd.params_[59] = "Insteon PLM"
SendCommand(cmd)
##device # 2
#cmd = Command.new(myDevFrom, myDevTo, myDevPriority, myDevType, myDevID)
##Add params...
#cmd.params_[56] = "73" # environment - Lighting Device
#cmd.params_[49] = "38" # Light (dimmable)
#cmd.params_[55] = "12\t11.22.33\n59\tConfiguration\n" # test lamp module
#cmd.params_[13] = "TEST LampLinc V2" # text to display
#cmd.params_[52] = "11"
#cmd.params_[53] = "2"
#cmd.params_[54] = "11.22.33"
#cmd.params_[59] = "Insteon PLM"
#SendCommand(cmd)
  
#Now, Fire the Done Detecting event...
cmd = Command.new(myDevFrom, myDevTo, myDevPriority, myDevType, 74) #Done detecting...
cmd.params_[59] = "Insteon PLM"
SendCommand(cmd)