Insteon Venstar Thermostat Module

From LinuxMCE
Revision as of 23:02, 28 February 2012 by Trippleg (Talk | contribs)

Jump to: navigation, search
Version Status Date Updated Updated By
710 Unknown N/A N/A
810 Working 8 Feb 2012 Trippleg
1004 Unknown N/A N/A
1204 Unknown N/A N/A
1404 Unknown N/A N/A
Usage Information

Uses Prebuilt Template 2197

You must update the folowing PLM Ruby code replacing 2209 with 2197:

756, 760, 373, 384

Overview

The Venstar Thermostat expects Insteon to send specific commands to the device, and each command is encapsulated in a mode. For example: In order to send a command to change the temperature. Venstar has to know what mode ie. Heat, Auto, Cool. Therefore; the code sent specifies mode and temperature setting. Since there is no built in mechanism for this In the DCE router one was created.

--Trippleg 00:22, 9 February 2012 (CET)trippleg

Added Template Sample --Trippleg 23:24, 24 February 2012 (CET)

Issuing A Command

This assumes you have already built and reconfigured the Ruby code for template 2197.

1. Click Climate, and pick the appropriate device.

2. Click Advanced

3. Click Send Command to Device.

Mode Commands

Off command = Works as programmed within LMCE

On command does not work. We have to issue a mode instead.

The following effectively turns the device ON.
   1. Send to this device the command select Set Heat/Cool 
   2. # 8 On/Off (string) Box place the following:
       For Auto String will = A
       For Cool String will = C
       For Heat String will = H 

Sending a command to change temperature

With this command we have to send both mode and temp to get it to set, otherwise the thermostat will ignore the request.

  1. Send to this device the command select Set Tempurature.
  2. # 5 Value To Assign (string) Box Place The following: Mode/Temperature
     For Cool Temperature Setting String will = C/72  for Cool at 72 degrees
     For Heat Temperature Setting String will = H/78  for Heat at 74 degrees
 (Both of the above temp controls work in all 3 modes sending the C or the H effectively tells the unit to change the temp at which the A/C or Heater turns on)


Reporting Device Status

This feature has not been enabled yet. Insteon does have the ability do do this, it just has not been coded for yet.

Template Sample

To Build the template I used the default Thermostat template and added some extra Device Data fields required By the Insteon PLM. Below are some template screen shots.

Please Note: You will need the updated version of the Insteon PLM. I am working on posting it to the existing wiki page. The code has been posted so it should be available in the current SVN Template2209-1.JPG

Template2209-2.JPG

Template2209-3.JPG