Difference between revisions of "Express Controls EZmotion (HSM 100)"

From LinuxMCE
Jump to: navigation, search
(Configuration)
Line 45: Line 45:
  
 
48 Value (int) : <the time in minutes can only be 6 or any increment of 6> <br>
 
48 Value (int) : <the time in minutes can only be 6 or any increment of 6> <br>
239 NodeID (int) : <the zwave nodeid>
+
239 NodeID (int) : <the zwave nodeid> <br>
 +
 
 +
Send Message
 +
 
 +
Then push the button on the EZmotion (HSM 100)
  
 
= Command classes =
 
= Command classes =

Revision as of 19:50, 28 September 2010

Version Status Date Updated Updated By
710 Unknown N/A N/A
810 Working,PnP as 3 multilevel sensors 4th May 2010 sambuca
1004 Unknown N/A N/A
1204 Unknown N/A N/A
1404 Unknown N/A N/A
Usage Information

About

The EZMotion is a 3-in-1 Z-Wave sensor. This is also sold by Innovus and Homeseer (HSM100)

Manuf ID1: 0x0 ID2: 0x1e, Prod Typ1: 0x0 Typ2: 0x2, Prod ID1: 0x0 ID2: 0x1

Features

  • Motion detection
  • Light sensor
  • Temperature sensor.

Setup

If you use SIS mode in your ZWave setup, this device should automatically be added as three multilevel sensors. If not, it is possible to set it up manually. If you are running SIS mode, you can delete the main device and re-add it as a motion detector, see below for details.

You will have one multilevel sensor added for the EZMotion. Find and open this from the device tree. We will change this to be the thermometer instance. Find the Port/Channel number. This is the node ID. Change the Port/Channel number to <node id>/3 (for instance 4/3 if your node id is 4), type to Thermometer, insert 49 in Capabilities, and save.

Add a new device below the ZWave Embedded Climate Interface using the same device template (Multilevel sensor). Insert <node id>/2 in Port/Channel number, insert 49 in Capabilities and save. This will be the brightness sensor. Please notice that the values returned from this sensor ranges from 0 to 100% and is relative to the light measured since X (see the manual).

Then we add the Motion detector. This will not be added automatically even when running the SIS mode. Open the ZWave Embedded Security Interface and click Create New Child. Select the Motion Detector template. Insert <node id> in Port/Channel number, Motion Detector in type, 133,96,49,112,132,128,114,119,134 in Capabilities, and save.

Reload router and you should receive events from all three sensors. The motion detector will also report a values(which is not sent to LMCE atm.). This value if the number of minutes since last motion was detected, and 0 if no motion was detected. See the manual for more information.

Configuration

To change the interval temperature and light is reported go to Home > My Devices > CORE > ZWave and chose "Send command to device". Select "SetWakeUp" and set parameters as follows:

48 Value (int) : <the time in minutes can only be 6 or any increment of 6>
239 NodeID (int) : <the zwave nodeid>

Send Message

Then push the button on the EZmotion (HSM 100)

Command classes

0x4 0x21 0x1

  • COMMAND_CLASS_MULTI_INSTANCE
  • COMMAND_CLASS_SENSOR_MULTILEVEL
  • COMMAND_CLASS_CONFIGURATION
  • COMMAND_CLASS_WAKE_UP
  • COMMAND_CLASS_ASSOCIATION
  • COMMAND_CLASS_BATTERY
  • COMMAND_CLASS_MANUFACTURER_SPECIFIC
  • COMMAND_CLASS_NODE_NAMING
  • COMMAND_CLASS_VERSION

Links

http://www.expresscontrols.com

http://www.expresscontrols.com/pdf/EZMotionOwnerManual.pdf