Danfoss RA Plus-w: Difference between revisions
Appearance
Langstonius (talk | contribs) No edit summary |
|||
| Line 14: | Line 14: | ||
* The thermostat communicates through the wireless Z-Wave standard just like the other Seluxit devices. | * The thermostat communicates through the wireless Z-Wave standard just like the other Seluxit devices. | ||
* The thermostat is secured against frost. | * The thermostat is secured against frost. | ||
= Device setup = | |||
== General information == | |||
* Supported wake up interval: 5 - 30 minutes | |||
* Clock adjustement: every 30 minutes | |||
== Day/Night button == | |||
* 1x short press: toggle between comfort and setback operation | |||
* 3x short press: network inclusion and exclusion | |||
* 1x long press (5 seconds): link test | |||
== Reset button == | |||
Remove the motor unit with the two release buttons from the thermostat to access the reset button. It's aside the sticker on right. | |||
* 1x press: factory reset, also resets home/node id | |||
== LED status feedback == | |||
* Fast blink: inclusion/exclusion/waiting for wakeup interval configuration | |||
* LED is lit: link test | |||
* Slow blink: operation failed | |||
* Short flash every 15s: battery low | |||
== Notes == | |||
Remove the motor when changing batteries, the device won't detect the change otherwise. | |||
= Links = | = Links = | ||
Revision as of 20:23, 28 June 2008

Status
Not yet confirmed working.
About
RA-PLUS-w is a programmable radiatorthermostat, that gives the possiblity to decrease the room temperature with about 3 degrees in chosen periods of the day.
Features
- By decresing the temperature in periods of the day the energy used for heating can be reduced without compromising on the comfort.
- The thermostat communicates through the wireless Z-Wave standard just like the other Seluxit devices.
- The thermostat is secured against frost.
Device setup
General information
- Supported wake up interval: 5 - 30 minutes
- Clock adjustement: every 30 minutes
Day/Night button
- 1x short press: toggle between comfort and setback operation
- 3x short press: network inclusion and exclusion
- 1x long press (5 seconds): link test
Reset button
Remove the motor unit with the two release buttons from the thermostat to access the reset button. It's aside the sticker on right.
- 1x press: factory reset, also resets home/node id
LED status feedback
- Fast blink: inclusion/exclusion/waiting for wakeup interval configuration
- LED is lit: link test
- Slow blink: operation failed
- Short flash every 15s: battery low
Notes
Remove the motor when changing batteries, the device won't detect the change otherwise.