Difference between revisions of "Danfoss RA Plus-w"
From LinuxMCE
Langstonius (Talk | contribs) |
m (→Features) |
||
Line 14: | Line 14: | ||
* The thermostat communicates through the wireless Z-Wave standard just like the other Seluxit devices. | * The thermostat communicates through the wireless Z-Wave standard just like the other Seluxit devices. | ||
* The thermostat is secured against frost. | * The thermostat is secured against frost. | ||
+ | = Device setup = | ||
+ | == General information == | ||
+ | * Supported wake up interval: 5 - 30 minutes | ||
+ | * Clock adjustement: every 30 minutes | ||
+ | |||
+ | == Day/Night button == | ||
+ | * 1x short press: toggle between comfort and setback operation | ||
+ | * 3x short press: network inclusion and exclusion | ||
+ | * 1x long press (5 seconds): link test | ||
+ | == Reset button == | ||
+ | Remove the motor unit with the two release buttons from the thermostat to access the reset button. It's aside the sticker on right. | ||
+ | * 1x press: factory reset, also resets home/node id | ||
+ | == LED status feedback == | ||
+ | * Fast blink: inclusion/exclusion/waiting for wakeup interval configuration | ||
+ | * LED is lit: link test | ||
+ | * Slow blink: operation failed | ||
+ | * Short flash every 15s: battery low | ||
+ | == Notes == | ||
+ | Remove the motor when changing batteries, the device won't detect the change otherwise. | ||
= Links = | = Links = |
Revision as of 21:23, 28 June 2008
Contents
Status
Not yet confirmed working.
About
RA-PLUS-w is a programmable radiatorthermostat, that gives the possiblity to decrease the room temperature with about 3 degrees in chosen periods of the day.
Features
- By decresing the temperature in periods of the day the energy used for heating can be reduced without compromising on the comfort.
- The thermostat communicates through the wireless Z-Wave standard just like the other Seluxit devices.
- The thermostat is secured against frost.
Device setup
General information
- Supported wake up interval: 5 - 30 minutes
- Clock adjustement: every 30 minutes
Day/Night button
- 1x short press: toggle between comfort and setback operation
- 3x short press: network inclusion and exclusion
- 1x long press (5 seconds): link test
Reset button
Remove the motor unit with the two release buttons from the thermostat to access the reset button. It's aside the sticker on right.
- 1x press: factory reset, also resets home/node id
LED status feedback
- Fast blink: inclusion/exclusion/waiting for wakeup interval configuration
- LED is lit: link test
- Slow blink: operation failed
- Short flash every 15s: battery low
Notes
Remove the motor when changing batteries, the device won't detect the change otherwise.