Difference between revisions of "Düwi ZW ESJ 05436"

From LinuxMCE
Jump to: navigation, search
(Links: Added a link to an english version of the manual)
(Info)
Line 31: Line 31:
 
* Micro fuse: T 8 A H
 
* Micro fuse: T 8 A H
 
* Standby : < 1 W
 
* Standby : < 1 W
 +
== Config ==
 +
The running time can be adjusted using Z-Wave parameter #0 (2 bytes):
  
 +
running time:
 +
0x00: continuous operation
 +
0x01-0x7F: 1-127 seconds
 +
0x80-0xFE: 130-1390 seconds
 +
0xFF: 120 seconds (default)
 +
 +
One byte for each direction (example: Z-Wave parameter #0 = 8737 => 34s/33s)
  
 
== Links ==
 
== Links ==

Revision as of 19:27, 26 September 2012

Version Status Date Updated Updated By
710 According to category, Works without caveats 26th July 2010 Valent
810 According to category, Works without caveats 26th July 2010 Valent
1004 Unknown N/A N/A
1204 Unknown N/A N/A
1404 Unknown N/A N/A
Usage Information
Duwi zw esj 05436.jpg

Düwi ZWave Sun Window Blind Insert

Info

Düwi ZW ESJ 05436 Z-Wave has dual function:

Switch/Dimmer

Serves for the switching or dimming of connected lights either via radio signals or directly over clipped-on radio-rockers.

Sun blind control

The Düwi wireless insert of sun blind is for the wireless opening and closing of window blinds, shutters,sun blinds and electronic gates. The wireless sun blind automatically turns off the contact after about 2 minutes (value set at delivery) in order to protect the motor


Technical specifications
  • Switching capacity
    • ohmic 1800W
    • 460VA (motors + luminescent lamps)
    • 500W incandescent bulbs
  • Operating voltage: 230 V~, 50 Hz
  • Switching time: 2 minutes (time period is factory set)
  • Micro fuse: T 8 A H
  • Standby : < 1 W

Config

The running time can be adjusted using Z-Wave parameter #0 (2 bytes):

running time:
0x00: continuous operation 
0x01-0x7F: 1-127 seconds 
0x80-0xFE: 130-1390 seconds
0xFF: 120 seconds (default)

One byte for each direction (example: Z-Wave parameter #0 = 8737 => 34s/33s)