Insteon PLM Ruby Code 373

From LinuxMCE
Revision as of 01:27, 6 January 2008 by Ddamron (Talk | contribs)

(diff) ←Older revision | view current revision (diff) | Newer revision→ (diff)
Jump to: navigation, search
#### Written by Dan Damron
#### #373 Private Method Listing ####

def mainStart() ## This is called FIRST, reruns cannot call this.
  #Get the PLM Database
  sendGetLink
  #get Child devices
  log('Finding Children..')
  device_.childdevices_.each{|c| $children[device_.childdevices_[c.to_s.to_i].devdata_[12].chomp.lstrip.rstrip] = c.to_s.to_i}
  $children.keys.each{|c| log(c + ' = ' + $children[c].to_s)}
  log('reading stored Child configuration:')

  $children.keys.each{|c|
    #Get each Childs configuration
    getdeviceconfig(c)  #
    #the above getdeviceconfig packs $configparams array
    log('Configuration for ' + c + ' = ' + $configparams.inspect.to_s)
  }

  log('********************************************************')
  #get childs actual configuation and status
  $children.keys.each{|c| sendGetChildStatus(c)}
  SndIns()
end
def mainRestart()
  #We have hashes already set up.
  $childdatabases.each_key{|@insteonID|
    sendGetChildStatus(@insteonID)}
  SndIns()
end

def setdeviceconfig(insteonid, configurestring)
  @deviceid = $children[insteonid]
  @cmdfrom = device_.devid_
  @cmdto = 4 #general info plugin
  @priority = 1
  @type=1 #command
  @cmdid = 246

  #set up command..
  @cmd = Command.new(@cmdfrom, @cmdto, @priority, @type, @cmdid)
  @cmd.params_[2] = @deviceid.to_s
  @cmd.params_[52] = '59' # Configuration
  @cmd.params_[5] = configurestring
  SendCommand(@cmd)
  #log('SetDeviceConfig:' + configurestring)
  #log('Configuration Saved - will be available on next reload')
end

def getdeviceconfig(insteonid)
  @deviceid = $children[insteonid]
  @configstring = ''
  begin
    @configstring = device_.childdevices_[@deviceid].devdata_[59].to_s
  rescue
    log('Device ID = ' + @deviceid.to_s)
    log($red + 'Error - Child has no configuration'+ $grey)
    log('Setting initial value of "****************"')
    setdeviceconfig(insteonid, ('*' * 16))
    @configstring = '*' * 16
    sendPing(insteonid)
  end
  if @configstring == ''
    $configparams = ['****************']
    log('CAUGHT BLANK RECORD')
    setdeviceconfig(insteonid, ('*' * 16))
    sendPing(insteonid)
  else
    $configparams = @configstring.unpack('a16' * (@configstring.length / 16))

  end
  #log($yellow + 'getdeviceconfig:' + $configparams.inspect + $grey)
  #add the configuration parameters to the child database
  $childdatabases[insteonid] = $configparams
  #get the device type

end

def sendGetLink()
  #lets just see exactly what is in the PLM database
  param = {'Command' => 'GetLnk'}
  $cmdqueue << param
  SndIns()
end

def sendGetNext()
  param = {'Command' => 'GetNext'}
  if $wAIT == true
    $cmdqueue.insert(1, param)
  else
    $cmdqueue.insert(0,param)
  end
  SndIns()
end

def sendRemoteGetLink(insteonID)
  # Read First ALDB Record
  # a few variables need to be set up here..
  $recordof = insteonID # save the insteon ID
  insID = insteonID.chomp.split('.') # get the seperate bytes
  $remoteDBOffsetMSB = 0x0F # initial offset
  $remoteDBOffsetLSB = 0xF8 # initial LSB offset
  param = {'Command' => 'SndIns',
    'Parameter1' => insID[0], #HB
    'Parameter2' => insID[1], #MB
    'Parameter3' => insID[2], #LB
    'Parameter4' => '0F', #Flags
    'Parameter5' => '28', #Cmd1
    'Parameter6' => "%X" %$remoteDBOffsetMSB #Cmd2 Set MSB Offset
  }
  $cmdqueue << param
  # repeat last param for each byte to read (F8..FF)=first record

  for x in 0..7
    param = {'Command' => 'SndIns',
      'Parameter1' => insID[0], #HB
      'Parameter2' => insID[1], #MB
      'Parameter3' => insID[2], #LB
      'Parameter4' => '0F', #Flags
      'Parameter5' => '2B', #Cmd1 Peek
      'Parameter6' => "%X" %($remoteDBOffsetLSB + x) #Cmd2
    }

    $cmdqueue << param
  end

end

def sendRemoteGetNext(insteonID)
  insID = insteonID.chomp.split('.') # get the seperate bytes
  ### Do NOT forget to check to see if we need to decrease the MSB

  if $remoteDBOffsetLSB == 0x00
    #OffsetMSB needs to be decreased, and LSB needs reset.
    $remoteDBOffsetMSB = $remoteDBOffsetMSB - 1
    $remoteDBOffsetLSN = 0xFF # the next line will decrease this by 8
  end
  # decrease DBOffsetLSB by 0x08
  $remoteDBOffsetLSB = $remoteDBOffsetLSB - 0x08

  for x in 0..7
    param = {'Command' => 'SndIns',
      'Parameter1' => insID[0], #HB
      'Parameter2' => insID[1], #MB
      'Parameter3' => insID[2], #LB
      'Parameter4' => '0F', #Flags
      'Parameter5' => '2B', #Cmd1 Peek
      'Parameter6' => "%X" %($remoteDBOffsetLSB + x) #Cmd2
    }
    #log('sendRemoteGetNet:added to queue:' + param.inspect)
    if $wAIT == true
      $cmdqueue.insert(x +  1, param)
    else
      $cmdqueue.insert(x,param)
    end

    
  end
end

### Main command parsing routine is EZToDCE
def EZToDCE(param)
  #param contains a hash of EZBridge command structure
  #log($blue + 'Queue:' + $cmdqueue[0].inspect + $grey)
  #log($blue + 'Param:' + param.inspect + $grey)
  #log($blue + 'currentcmd:' + $currentcmd.to_s + $grey)
  #checkWait(param)
  case param['Response']
    # Standard RESPONSES (to commands)
  when 'GetRevision' 	# Special Response
    log('-----|---------GetRevision:' + param['Parameter1'])

  when 'GetLatLong'  	# Special Response
    log('-----|---------GetLatLong: Lat=' + param['Lat'] + ', Long=' + param['Long'])

  when 'SetLatLong'
    if param['Parameter1'] = 'True' then
      log('-----|---------SetLatLong: Ok')
    else
      log('-----X---------SetLatLong: FAILED!')
    end
  when 'SetPasswd'

  when 'SetTimeZone'

  when 'GetClock'		# Special Response

  when 'SetClock'

  when 'SetNTPServer'

  when 'Upgrade'

  when 'NetCfg'

  when 'Reset'
    #Reset Response

    cmdComplete
    SndIns()
  when 'LstTimers'  	# Special Response


  when 'ClrTimers'

  when 'AddTimer'

  when 'GetTimer'   	# Special Response

  when 'SetTimer'

  when 'DelTimer'

  when 'GetVersion' 	# Special Response

  when 'SndGrp'

  when 'SndIns' # response from SndIns
    ### BUG FOUND ### When the EZBridge receives a command from an EXTERNAL source
    ### ie not from this device, cmdqueue will be nil, and the code below
    ### fails.  Have to check against that.
    if $cmdqueue.length > 0
      #First, check the response to make sure the command made it ok.
      if param['Parameter9'].to_i == 6 #Ack received
	#log('Sending to ProcessACK')
        processACK(param)				
      else # NACK received - command failed.
        log('Command NACKED')
      end
    else
      #Response received for another device.
      log('Response detected for a command that was not sent by me')
    end
  when 'SndX10'
    log('Response detected for SndX10')

  when 'StLnk'

  when 'CancelLnk'

  when 'SetDev'

  when 'RstPLM'
    #Reset Response
    $timeout = 3
    cmdComplete
    SndIns()

  when 'GetLnk'
    if param['Parameter3'].to_i == 6 #ack
      log('GetLnk ACKED')
      #if we get this, we should get a AllLink Record Response next
    else
      log('GetLnk NACKED')
      # The PLM is BLANK
      #have to add records to the PLM here.
      cmdComplete
      ### FINISHED WITH GetLnk
      checkChildRecordsinPLM()
    end
  when 'GetNext'
    if param['Parameter3'].to_i == 6 #ack
      log('sendGetNext ACKED')
      #if we get this, we should get a AllLink Record Response next
    else
      log('sendGetNext NACKED')
      #we get this when there are no more records
      cmdComplete
      #FINISHED with GetNext
      # if we are here, we are in config mode
      # so, next is to check to make sure the
      # childrens insteon ID is in the PLM
      checkChildRecordsinPLM()
      SndIns()
    end

  when 'SetCfg' # response from Setcfg command
    if param['Parameter4'].to_i == 6 #ack
      log('SetCfg Completed')
      cmdComplete
      SndIns()
    else
      log('SetCfg NACKED')
    end 
  when 'GetLnkData'

  when 'LEDON'

  when 'LEDOFF'

  when 'MngLnk'
    if param['Parameter12'].to_i == 6
      log('MngLnk => ACK')
    else
      log('MngLnk => NACK')
    end
    cmdComplete
    SndIns()

  when 'GetCfg' 		# Special Response

  when 'LstMacros'	# Special Response

  when 'ClrMacros'

  when 'AddMacro'

  when 'GetMacro'		# Special Response

  when 'SetMacro'

  when 'DelMacro'

  when 'LstDevices'	# Special Response

  when 'ClrDevices'

  when 'AddDevice'

  when 'GetDevice'	# Special Response

  when 'SetDevice'

  when 'DelDevice'

  when 'LstZones'

  when 'ClrZones'

  when 'AddZone'

  when 'GetZone'

  when 'SetZone'

  when 'DelZone'

  when 'AddDevZone'

  when 'DelDevZone'

    # Response Messages
  when 'InsExtMsg' 

  when 'InsStdMsg'
    case $currentcmd # if this msg is part of a response, the Insteon Cmd1 will be saved here.
    when 0x0
      #log('REROUTING to processExternalCommand(param)')
      processExternalCommand(param)
    when 0x1 #Assign to Group 
      ### This is a broadcast message sent
      # from a PING command
      # or from a StartLink...
      log('Caught Assign to Group Message from Device')
      ### BUG HERE
      #have to check flags to see if this is a broadcast message
      log('Checking  if this is a broadcast message')
      log('Flags:' + param['Parameter9'])
      if (param['Parameter9'].hex & 0x80) == 0x80
        log('Message IS BROADCAST')
        #recvComplete
        processDeviceInfo(param)
        
        # check to see if current cmd is for this broadcast..
        log('Current Command:' + $cmdqueue[0]['Parameter5'])
        if $cmdqueue[0]['Parameter5'] == '10'
          #log('Clearing PING Command')
          $currentcmd = 0
          cmdComplete
          SndIns()
        else
          log('CURRENT CMD IS NOT PING - NOT CLEARING')
        end

      else
        log('Message is NOT Broadcast')
      end
    when 0x2 #Delete from Group
    when 0x10 # PING
      #this is where I catch the InsStdMsg for ping.
      log('Caught PING Message from Device')
      $currentcmd = 1
				
    when 0x11 # ON
      log('Caught Insteon ON from INTERNAL source')
      insHb = param['Parameter3'] # From
      insMb = param['Parameter4']
      insLb = param['Parameter5']

      insID = insHb + "." + insMb + "." + insLb
      myDevFrom = $children[insID]
      log('Current DIM level:' + param['Parameter11'])

      reportStatus(myDevFrom, hextopercent(param['Parameter11']))

      $currentcmd = 0
      cmdComplete

      SndIns()
    when 0x13 # OFF
      insHb = param['Parameter3'] # From
      insMb = param['Parameter4']
      insLb = param['Parameter5']
      insID = insHb + "." + insMb + "." + insLb
      myDevFrom = $children[insID]
      reportStatus(myDevFrom, 0)

      $currentcmd = 0
      cmdComplete
      log('EVENT and state SENT!!!.48:[10]=0')
      SndIns()
    when 0x19 # Status Report
      # now to clear the currentcmd and remove command from the queue
      $currentcmd = 0
      cmdComplete

      log('Processing 0x19 Status Report')
      #This is where I get the database delta (in cmd1)
      insHb = param['Parameter3'] # From
      insMb = param['Parameter4']
      insLb = param['Parameter5']
      insID = insHb + "." + insMb + "." + insLb
      #First, to compare the DB Delta with current config.
      #Database Delta...
      delta = param['Parameter10'].to_s
      log($redBack + 'Database Delta=' + delta + $blackBack)
      log($redBack + 'Configuration is:' + getdeltafromconfig(insID) + $blackBack)
      if delta == getdeltafromconfig(insID)
	if $children[insID] != nil
          myDevFrom = $children[insID]
          myDevTo = -1000 #DCE Router
          myPriority = 1
          myType = 2 #Event

          #Send an EVENT to report STATE ONLY if database has not changed
          # AND child exists in pluto
          reportStatus(myDevFrom, hextopercent(param['Parameter11']))
	end
      else
        log('Databse CHANGED -getting remote database')
        #here, I have to WIPE the databse
        # to prepare it for new data
	### here is where the DAMN CONFIG was reset!!!
	oldconfigstring = $childdatabases[insID][0]
        $childdatabases[insID] = [oldconfigstring]
        log('Setting Database Config')
        $childdatabases[insID][0][6..7] = delta
        savechilddatabases(insID)
        sendRemoteGetLink(insID)
      end
      # finally, to check execute next command...
      SndIns()
    when 0x28 # Set Address MSB
      log('Received SET Address MSB from remote device')
      $currentcmd = 0
      $remoteLinkRecord = ''
      cmdComplete
      SndIns()
    when 0x2B # peek
      ### BUG HERE... have to verify response is a PEEK command
      #response command is stored in parameter10
      if param['Parameter10'].hex == 0x2B # this is the peek command
        cmdComplete
        log('Received PEEK from remote Device! DATA=' + param['Parameter11'])
        checkPeekData(param)
        $currentcmd = 0
        SndIns()
      else
        log('Waiting for remote PEEK response, but got :' + param['Parameter10'])
      end
    else
    end

  when 'X10Msg'
    log($purple + 'X10 Message Received' + $grey)
    if param['Parameter4'].hex == 0x00
      log('This byte is a House/Unit Code')
      hn = param['Parameter3'][0].chr
      ln = param['Parameter3'][1].chr
      $x10byte1 = $X10HouseCodes[hn]
      $x10byte1 += $X10UnitCodes[ln]
      log('Translated X10 House/Unit Code:' + $x10byte1)
    else
      log('This byte is a House/Command Code')
      hn = param['Parameter3'][0].chr
      ln = param['Parameter3'][1].chr
      #$x10byte2 = $X10HouseCodes[hn]
      $x10byte2 = $X10CommandCodes[ln]
      log('Translated X10 Command Code:' + $x10byte2)
      log('X10 Command ready to send:' + $x10byte1 + ' ' + $x10byte2)
      case $x10byte2
      when 'On'
        #Send ON to lmnce
        if $children[$x10byte1] == nil
          log('I do not control this X10 device')
        else
          cmd = Command.new(device_.devid, -1000, 1, 1, 192)
          SendCommand(cmd)
        end
        $x10byte1 = ''
        $x10byte2 = ''
      when 'Off'
        #Send OFF to lmnce
        if $children[$x10byte1] == nil
          log('I do not control this X10 device')
        else
          cmd = Command.new(device_.devid, -1000, 1, 1, 193)
          SendCommand(cmd)
        end
        $x10byte1 = ''
        $x10byte2 = ''
      when 'Bright'
      when 'Dim'
      when 'All Lights Off'
      when 'All Lights On'
      when 'Status Request'
      when 'Hail Ack'
      end
		
    end
  when 'InsLnkSts'
    log('InsLnkSts Received')

  when 'BtnRpt'
    log('Button Report Received')
  when 'UsrRst'
    log('User Reset Response Received')
  when 'GrpEvntRpt'
    log('Group Event Report Received')

  when 'LnkData'
    processLnkData(param)
    # Other messages
  when 'PLMTimeout'
    log('PLM Timeout detected.. resetting EZBridge')
    resetcmd = {'Command' => 'Reset'}
    if $wAIT == true
      $cmdqueue.insert(1, resetcmd)
    else
      $cmdqueue.insert(0,resetcmd)
    end
    sleep 15
    $wAIT = false
    SndIns()
  when 'PLMEchoError' # Have not seen this since a1.23
    # error sending command to PLM, reset command and try again
    log('-----XXXXXXX' + param['Response'])
    resetcmd = {'Command' => 'Reset'}
    if $wAIT == true
      $cmdqueue.insert(1, resetcmd)
    else
      $cmdqueue.insert(0,resetcmd)
    end

    sleep 15
    $wAIT = false
    SndIns()
  when 'LongAck'
    log('-----XXXXXXX' + param['Response'])
    # Error - seems to show up after PLMEchoError
    resetcmd = {'Command' => 'Reset'}
    if $wAIT == true
      $cmdqueue.insert(1, resetcmd)
    else
      $cmdqueue.insert(0,resetcmd)
    end
    sleep 15
    $wAIT = false
    SndIns()
  else
    log('-----XXXXXXX UNKNOWN Response Received:' + param['Response'])
  end

end

### Support routine for EZToDCE
def processLnkData(param)
  #Caught a LnkData Response
  log('LnkData Message Received')
  insteonID = padhex(param['Parameter5']) + '.' + padhex(param['Parameter6']) + '.' + padhex(param['Parameter7'])
  group = param['Parameter4']
  recflags = param['Parameter3']
  lnkdata1 = param['Parameter8']
  lnkdata2 = param['Parameter9']
  lnkdata3 = param['Parameter10']
  #pack string to store for PLM Database
  @currentrecord = recflags + group
  @currentrecord += param['Parameter5'] + param['Parameter6'] + param['Parameter7']
  @currentrecord += lnkdata1 + lnkdata2 + lnkdata3

  #Add to plmdatabase
  $plmdatabase << @currentrecord
  log('PLM database=' +$plmdatabase.inspect)
  if (recflags[0] & 0x80) == 0x80 # Record is in use if true 
  end
  if (recflags[0] & 0x40) == 0x40 # Controller if true
    log('Controller')
  else
    log('Responder')
  end

  log('Insteon ID:' + insteonID + ', Group:' + group)

  cmdComplete
  sendGetNext()		

end
### Support Routine for EZToDCE
def processExternalCommand(param)
  #there is no current command 
  # THIS IS COMING FROM AN OUTSIDE SOURCE
  #EG: Manually turning Light Switch On/Off
  # process this command.
  # Note, this is a standard message
  ### have to check here if child is mine!

  # This is where I have to check for a broadcast command..
  #if so, search the child databases for responders,
  #and fire events for each responder.
  #Message flag is in parameter9 Group command 0xCx (All-Link Broadcast Message Pg 42.)
  #Group is in parameter8
  #From InsteonID is parameters 3, 4, 5
  if (param['Parameter9'].hex & 0xC0) == 0xC0 # Message is Broadcast 
    log('Rerouting to processBroadcastMessage')
    processBroadcastMessage(param)
  else
    log('Process External Command:')
    log('Param:' + param.inspect)

    # there is no ack here.  Simply Send EVENTS back to DCE
    # and Complete the recv..
    case param['Parameter10'].hex #this is the command
    when 0x01 #Assign to Group
      log('Caught EXTERNAL Assign to Group')
      processDeviceInfo(param)
      recvComplete
    when 0x02 #Delete from Group
      log('Caught EXTERNAL Delete from Group')
      recvComplete
    when 0x10 # PING
      log('Caught EXTERNAL Insteon PING result')
      recvComplete


    when 0x11 #ON
      log('Caught EXTERNAL Insteon ON command result')
      #on level is in cmd2
      insHb = param['Parameter3'] # From
      insMb = param['Parameter4']
      insLb = param['Parameter5']
      insID = insHb + "." + insMb + "." + insLb
      log('From:' +insID)
      log('Device:' + $children[insID].to_s)
      myDevFrom = $children[insID]
      # check to see if I own child
      if myDevFrom == nil
        log('I do not control this device.')
      else
	reportStatus(myDevFrom, hextopercent(param['Parameter11']))
        $currentcmd = 0
      end
      recvComplete



    when 0x13 #OFF
      log('Caught EXTERNAL Insteon OFF result')
      #on level is in cmd2
      insHb = param['Parameter3'] # From
      insMb = param['Parameter4']
      insLb = param['Parameter5']
      insID = insHb + "." + insMb + "." + insLb
      myDevFrom = $children[insID]
      if myDevFrom == nil
        log('I do not control this device.')
      else

	reportStatus(myDevFrom, 0)

        $currentcmd = 0
        log('EVENT and state  SENT!!!.48:[10]=0')
      end
      recvComplete
    when 0x15; log('Caught EXTERNAL Insteon Brighten Result')
    when 0x16; log('Caught EXTERNAL Insteon DIM Result')
    when 0x24; log('Caught EXTERNAL Insteon DO EE READ')
    when 0x28; log('Caught EXTERNAL Insteon SET ADDRESS MSB')
    when 0x29; log('Caught EXTERNAL Insteon POKE')
    when 0x2A; log('Caught EXTERNAL Insteon POKE EXTENDED')
    when 0x2B; log('Caught EXTERNAL Insteon PEEK')
    when 0x2C; log('Caught EXTERNAL Insteon PEEK INTERNAL')
    when 0x2D; log('Caught EXTERNAL Insteon POKE INTERNAL')
    else
      log('Unknown EXTERNAL Insteon Command.')
    end
  end
end
### Support Routine for EZToDCE
def processACK(param)
  #log('In ProcessACK: Param7:' + param['Parameter7'])
  #log('CurrentCmd=' + $currentcmd.to_s)
  case param['Parameter7'].hex #Received an ack to THIS command
  when 0x1 #Assign to Group
    log('Got Assign to Group ACK')
    $currentcmd = 0x01
    $cmdqueue[0]['Command'] = 'InsStdMsg'
    #processDeviceInfo(param)
    #cmdComplete
  when 0x2 #Delete from Group
  when 0x10 # PING
    log('Got PING ACK')
    #cmdComplete
    $currentcmd = 0x1
    $cmdqueue[0]['Command'] = 'InsStdMsg'
  when 0x11 #ON
    $currentcmd = 0x11
    $cmdqueue[0]['Command'] = 'InsStdMsg'
  when 0x13 #OFF
    $currentcmd = 0x13
    $cmdqueue[0]['Command'] = 'InsStdMsg'
  when 0x15 #Bright
    $currentcmd = 0x15
    $cmdqueue[0]['Command'] = 'InsStdMsg'
  when 0x16 #DIM
    $currentcmd = 0x16
    $cmdqueue[0]['Command'] = 'InsStdMsg'
  when 0x17 #Start Manual Change
  when 0x18 #Stop Manual Change
  when 0x19 #Status Request
    # Status Request Acked - get ready for InsStdMsg
    $currentcmd = 0x19
    # change cmd to reflect InsStdMsg
    $cmdqueue[0]['Command'] = 'InsStdMsg'
  when 0x24
    log('Caught ACK for Insteon DO EE READ')
    $currentcmd = 0x24
    $cmdqueue[0]['Command'] = 'InsStdMsg'
  when 0x28
    log('Caught ACK for Insteon SET ADDRESS MSB')
    $currentcmd = 0x28
    $cmdqueue[0]['Command'] = 'InsStdMsg'
      
  when 0x29
    log('Caught ACK for Insteon POKE')
    $currentcmd = 0x29
    $cmdqueue[0]['Command'] = 'InsStdMsg'
      
  when 0x2A
    log('Caught ACK for Insteon POKE EXTENDED')
    $currentcmd = 0x2A
    $cmdqueue[0]['Command'] = 'InsStdMsg'
      
  when 0x2B
    #log('Caught ACK for Insteon PEEK')
    $currentcmd = 0x2B
    $cmdqueue[0]['Command'] = 'InsStdMsg'
      
  when 0x2C
    log('Caught ACK for Insteon PEEK INTERNAL')
    $currentcmd = 0x2C
    $cmdqueue[0]['Command'] = 'InsStdMsg'
      
  when 0x2D
    log('Caught ACK for Insteon POKE INTERNAL')
    $currentcmd = 0x2D
    $cmdqueue[0]['Command'] = 'InsStdMsg'
      
  else
    log('Unknown Insteon Cmd1')
  end
end


def checkPeekData(param)

  $remoteLinkRecord += param['Parameter11'].hex.chr
  log('CURRENT REMOTE RECORD IS:')
  debug($remoteLinkRecord)
  if $remoteLinkRecord.length == 8
    log('REMOTE RECORD COMPLETE!')
    processRemoteRecord(param)
    $remoteLinkRecord = ''
  end
end


def processRemoteRecord(param)
  #have to find MY address
  insHb = param['Parameter3'] # From
  insMb = param['Parameter4']
  insLb = param['Parameter5']
  insID = padhex(insHb) + "." + padhex(insMb) + "." + padhex(insLb)

  log('Processing remote Record below:')

  @flags = "\nFrom Device:" + insID + "\nFlags:\n"

  if ($remoteLinkRecord[0] & 0x02) == 0x02 # High water mark
    @flags += "Not the last record\n"
  else
    @flags += "This IS the last record\n"
  end

  if ($remoteLinkRecord[0] & 0x80) == 0x80 # Record is in use
    @flags += "Record In Use\n"
    if ($remoteLinkRecord[0] & 0x40) == 0x40 # Controller/Responder
      @flags += "I am a Controller of "
    else
      @flags += "I am a Responder of "
    end
    @insteonID = padhex("%X" %$remoteLinkRecord[2]) + '.'
    @insteonID += padhex("%X" %$remoteLinkRecord[3]) + '.'
    @insteonID += padhex("%X" %$remoteLinkRecord[4])
		
    @group = "%X" %$remoteLinkRecord[1]
    @flags += @insteonID + " Group:" + @group
    @work = padhex("%X" %$remoteLinkRecord[0]) #Control byte
    @work += padhex("%X" %$remoteLinkRecord[1]) # Group
    @work += padhex("%X" %$remoteLinkRecord[2]) # ID HB
    @work += padhex("%X" %$remoteLinkRecord[3]) # ID MB
    @work += padhex("%X" %$remoteLinkRecord[4]) # ID LB
    @work += padhex("%X" %$remoteLinkRecord[5]) # Data1
    @work += padhex("%X" %$remoteLinkRecord[6]) # Data2
    @work += padhex("%X" %$remoteLinkRecord[7]) # Data3
    log('adding to:' + insID)
    log('Value:' + @work)
    $childdatabases[insID] << @work #add it to the database
    log('Current Database:' + $childdatabases.inspect)
    #now to save the database to configuration.
    savechilddatabases(insID)
    # Now to check to see if the child exists as a record
    if $childdatabases[@insteonID] == nil
      log('InsteonID is NEW, adding Child database entry')
      $childdatabases[@insteonID] = ['****************']
      $rerun = true
      sendAddtoPLM(@insteonID)
      sendPing(@insteonID)
    else
      log('InsteonID:' + @insteonID.to_s + 'seems to exist in child databases')
      log('CDB:' + $childdatabases.inspect)

    end
  else
    @flags += "Record NOT in use\n"
  end
  log($aqua + @flags + $grey)
  log2(@flags)
  if ($remoteLinkRecord[0] & 0x02) == 0x02
    sendRemoteGetNext(insID)
  end
end

def savechilddatabases(insteonID)
  #This takes the $childdatabase hash+array and encodes it to
  # save it as a string.
  @work = ''
  #log($yellow + 'SaveChildDatabases::nitems:' + $childdatabases[insteonID].nitems.to_s)
  #log($childdatabases[insteonID].inspect + $grey)
  $childdatabases[insteonID].each{|record|
    @work += record
  }

  #now to save the string...
  setdeviceconfig(insteonID, @work)

end
def sendPing(insteonID)
  insID = insteonID.split('.')
  param = {'Command' => 'SndIns',
    'Parameter1' => insID[0],
    'Parameter2' => insID[1],
    'Parameter3' => insID[2],
    'Parameter4' => '0F',
    'Parameter5' => '10', #ID Request
    'Parameter6' => '00'}
  $cmdqueue << param
  log('PING Sent!')
end

def processDeviceInfo(param)
  ### temporary
  ### 12-24-07 Adding Device Template compatibility..
  #have to find MY address
  insHb = param['Parameter3'] # From
  insMb = param['Parameter4']
  insLb = param['Parameter5']

  insID = padhex(insHb) + "." + padhex(insMb) + "." + padhex(insLb)
  #set the devicecat and device subcat in the childdatabases
  #	0-1	Device Category
  #	2-3	Device SubCategory
  #	4-5	Device Firmware
  $childdatabases[insID][0][0..1] = param['Parameter6']
  $childdatabases[insID][0][2..3] = param['Parameter7']
  $childdatabases[insID][0][4..5] = param['Parameter8']
  savechilddatabases(insID)
  log('InsteonID: ' + insID)
  #log('Child Config AFTER update:' + $childdatabases[insID][0].to_s)
  log($yellow)
  case param['Parameter6'].hex
  when 0x0 # Generalized Controllers
    case param['Parameter7'].hex
    when 0x04; log('Found ControLinc [2430]')
    when 0x05; log('Found RemoteLinc [2440]')
    when 0x06; log('Found Icon Tabletop Controller [2830]')
    when 0x09; log('Found SignaLinc RF Signal Enhancer [2442]')
    when 0x0A; log('Found Balboa Instruments Poolux LCD Controller')
    when 0x0B; log('Found Access Point [2443]')
    when 0x0C; log('Found IES Color Touchscreen')
    end
  when 0x01 # Dimmable Lighting Control
    case param['Parameter7'].hex
      # all these devices are associated with Template 38
      # Light Switch (dimmable)
    when 0x00; log('Found LampLinc V2 [2456D3]')
    when 0x01; log('Found SwitchLinc V2 Dimmer 600W [2476D]')
    when 0x02; log('Found In-LineLinc Dimmer [2475D]')
    when 0x03; log('Found Icon Switch Dimmer [2876D]')
    when 0x04; log('Found SwitchLinc V2 Dimmer 1000W [2476DH]')
    when 0x06; log('Found LampLinc 2-pin [2456D2]')
    when 0x07; log('Found Icon LampLinc V2 2-pin [2456D2]')
    when 0x09; log('Found KeypadLinc Dimmer [2486D]')
    when 0x0A; log('Found Icon In-Wall Controller [2886D]')
    when 0x0D; log('Found SocketLinc [2454D]')
    when 0x13; log('Found Icon SwitchLinc Dimmer for Lixar/Bell Canada [2676D-B]')
    when 0x17; log('Found ToggleLinc Dimmer [2466D]')
    end
  when 0x02 # Switched Lighting Control
    case param['Parameter7'].hex
      # all these devices are associated with Template 37
      # Light Switch (ON/OFF)
			
    when 0x09; log('Found ApplianceLinc [2456S3]')
    when 0x0A; log('Found SwitchLinc Relay [2476S]')
    when 0x0B; log('Found Icon On Off Switch [2876S]')
    when 0x0C; log('Found Icon Appliance Adapter [2856S3]')
    when 0x0D; log('Found ToggleLinc Relay [2466S]')
    when 0x0E; log('Found Switchlinc Relay Countdown Timer [2476ST]')
    when 0x10; log('Found In-LineLinc Relay [2475D]')
    when 0x13; log('Found Icon SwitchLinc Relay for Lixar/Bell Canada [2676R-B]')
    end
  when 0x03 # Network Bridges
    case param['Parameter7'].hex
    when 0x01; log('Found PowerLinc Serial [2414S]')
    when 0x02; log('Found PowerLinc USB [2414U]')
    when 0x03; log('Found Icon PowerLinc Serial [2814S]')
    when 0x04; log('Found Icon PowerLinc USB [2814U]')
    when 0x05; log('Found Smartlabs Power Line Modem Serial [2412S]')
    end
  when 0x04 # Irrigation Control
    case param['Parameter7'].hex
      # all these devices are associated with Template 1780
      # Standard Irrigation Sprinkler

    when 0x00; log('Found Simplehomenet EZRain1 Sprinkler Controller')
    end
  when 0x05 # Climate Control
    case param['Parameter7'].hex
    when 0x00; log('Found Broan SMSC080 Exhaust Fan')
    when 0x01; log('Found Simplehomenet EZTherm')
    when 0x02; log('Found Broan SMSC110 Exhaust Fan')
    when 0x03; log('Found Venstar RF Thermostat Module')
    when 0x04; log('Found Simplehomenet EZStat Thermostat')
    end
  when 0x06 # Pool and Spa Control
    case param['Parameter7'].hex
    when 0x00; log('Found Simplehomenet EZPool')
    end
  when 0x07 # Sensors and Actuators
    case param['Parameter7'].hex
    when 0x00
    end
  when 0x08 # Home Entertainment
    case param['Parameter7'].hex
    when 0x00
    end
  when 0x09 # Energy Management
    case param['Parameter7'].hex
    when 0x00
    end
  when 0x0A # Built-In Appliance Control
    case param['Parameter7'].hex
    when 0x00
    end
  when 0x0B # Plumbing
    case param['Parameter7'].hex
    when 0x00
    end
  when 0x0C # Communication
    case param['Parameter7'].hex
    when 0x00
    end
  when 0x0D # Computer Control
    case param['Parameter7'].hex
    when 0x00
    end
  when 0x0E # Window Coverings
    case param['Parameter7'].hex
    when 0x00
    end
  when 0x0F # Access Control
    case param['Parameter7'].hex
    when 0x00
    end
  when 0x10 # Security, Health, and Safety
  when 0x11 # Surveillance
  when 0x12 # Automotive
  when 0x13 # Pet care
  when 0x14 # Toys
  when 0x15 # Timekeeping
  when 0x16 # Holiday
  end
  ### eventually, open a XML configuration script?
  ### or read saved data from mysql?
  ### most likely save this information to sql with device.
  ### eventually, IPKDB will be available to ping.
  log ('for Insteon ID:' + insID)
  log($grey)
end

def recvComplete
  # Clears the wait flag, but does not remove a command from the queue
  $wAIT = false
  log($green + "Receive Completed.  Checking command queue" + $grey)
  if $cmdqueue.nitems > 0 then
    log("Queue:" + $aqua + $cmdqueue.nitems.to_s + $grey + " : executing next command")
    SndIns()
  else
    log($yellow + 'Queue Empty.' + $grey)
    if $rerun == true
      log('RERUN=TRUE, RESTARTING')
      $rerun = false
      mainRestart()
    else
      log('RERUN Not needed')
      #report Child devices here.
      if $reported == false
        cmd = Command.new(device_.devid_, device_.devid_, 1, 1, 756)
        $reported = true
        SendCommand(cmd)
      end
    end

  end
end
def cmdComplete
  # Clears the wait flag, and removes the command from the queue.
  $wAIT = false
  $resetNext = 0
  $cmdqueue.delete_at(0)
  # now that THAT command is completed, check to see if there is
  # another command ready to transmit.
  log($green + "Command Completed." + $grey)
end
def checkWait(param)
  #Checks for response from current command.
  if $cmdqueue[0] != nil
    if $wAIT == true
      #log('CW:waiting for command to complete')
    else
      #log('CW:reports clear')
    end
  else
    log('------:)----checkWait: command queue is emtpy')
    if $wAIT == true #this should never happen
      log('------:(XXX-CheckWait: TRUE')
    end
  end
end

def plmparse(value)
  #THIS ROUTINE REPLACES parsestring()
  #this routine will PARSE the incoming stream into valid messages
  # value is the complete command
  param = {}
  #here is a special case, the PLM seems to lock up.
  if value == 0x15.chr 
    log('The PLM stopped responding')
    log('Please unplug it, and plug it back in')
    log('and do a quick reload router.')

  end
  while value.length > 2
    case value[1]
    when 0x62 # Special case, need to look at flags
      if (value[5] & 0x10) == 0x10 # check for extended flag
        cmdlen = 23
      else
        cmdlen = 9
      end
      param['Response'] = 'SndIns'
    when 0x50; cmdlen = 11; param['Response'] = 'InsStdMsg'
    when 0x51; cmdlen = 25; param['Response'] = 'InsExtMsg'
    when 0x68; cmdlen = 4 #Set Insteon ACK Message Byte
    when 0x71; cmdlen = 5 #Set Insteon ACK Message Two Bytes
    when 0x70; cmdlen = 4 #Set Insteon NACK Message Byte
    when 0x63; cmdlen = 5; param['Response'] = 'SndX10'
    when 0x52; cmdlen = 4; param['Response'] = 'X10Msg'
    when 0x61; cmdlen = 6; param['Response'] = 'SndGrp'
    when 0x56; cmdlen = 7; param['Response'] = 'GrpEvntRpt'
    when 0x58; cmdlen = 3 #All-Link Cleanup Status Report
    when 0x64; cmdlen = 5; param['Response'] = 'StLnk'
    when 0x65; cmdlen = 3; param['Response'] = 'CancelLnk'
    when 0x53; cmdlen = 10; param['Response'] = 'InsLnkSts'
    when 0x69; cmdlen = 3; param['Response'] = 'GetLnk'
    when 0x6A; cmdlen = 3; param['Response'] = 'GetNext'
    when 0x6C; cmdlen = 3 #Get All-Link Record for Sender
    when 0x57; cmdlen = 10; param['Response'] = 'LnkData'
    when 0x6F; cmdlen = 12; param['Response'] = 'MngLnk'
    when 0x67; cmdlen = 3; param['Response'] = 'RstPLM'
    when 0x6B; cmdlen = 4; param['Response'] = 'SetCfg'
    when 0x60; cmdlen = 9; param['Response'] = 'GetVersion'
    when 0x66; cmdlen = 6 #Set Host Device Category
    when 0x72; cmdlen = 3 # RF Sleep
    when 0x54; cmdlen = 3; param['Response'] = 'BtnRpt'
    when 0x6D; cmdlen = 3; param['Response'] = 'LEDON'
    when 0x6E; cmdlen = 3; param['Response'] = 'LEDOFF'
    else

      log('ERROR IN PLMPARSE- Unknown Command')
      debug(value)
	
      return ''
    end

    #Now we know the length the command should be, see if we have it.
    #log('waiting for ' + cmdlen.to_s + ' characters...')
    #log('length of current input is ' + value.length.to_s)
    if value.length >= cmdlen
      #log('GOT whole response')
      #Yes, we have the whole command, Pack it in param
      for byt in 1..cmdlen
        param['Parameter' + byt.to_s] = padhex("%X" %value[byt - 1])
      end
      #now remove it from the string..
      value = value.slice(cmdlen, value.length - cmdlen)
      #Send it off for parsing
      #log('Sending to EZToDCE:' + param.inspect.to_s)
      EZToDCE(param)
    else
      #log('Still waiting...')
      #no, we have NOT received the whole command.

    end
  end
  return value
end

def rawX10(value)

  x10MSN = $X10HouseCodes.index[value[0..0]]
  x10LSN = $X10UnitCodes.index[value[1..1]]
  return x10MSN + x10LSN
end

def X10Flag(value)
  return + $X10CommandCodes.index[Value] + '0'
end

def SndIns
  # create a new PLM command for SndIns
  if $wAIT == false
    #log('SndIns:currentcmd=' + $currentcmd.to_s)

    if $cmdqueue.nitems > 0
      log("SndIns:Queue:" + $aqua + $cmdqueue.nitems.to_s + $grey)
      #log('SndIns:' + $cmdqueue.inspect)
      param = $cmdqueue[0]
      ### have to figure out the command byte 2 here
      work = '02'.hex.chr + plmcommand(param)
      ### PLM command compilation
      for loop in 2..param.keys.nitems
        @dummy = param['Parameter' + (loop - 1).to_s].to_s
        work+= @dummy.hex.chr
      end
      conn_.Reconnect()
      debug(work)
      conn_.Send(work)
      #sleep 0.1
      $wAIT = TRUE
    else
      log($yellow + 'Queue Empty.' + $grey)
      if $rerun == true
        log('RERUN=TRUE, RESTARTING')
        $rerun = false
        mainRestart()
      else
        log('RERUN Not needed')
      end

    end
  else
    log('X-----------SndIns: Waiting for response to:' +  $cmdqueue[0]['Command'].to_s)
    log('X-----------SndIns: Current Queue Length:' + $cmdqueue.nitems.to_s)
  end
end
def plmcommand(param)
  ### this returns the proper Byte2 for the command.
  case param['Command']
  when 'GetVersion'; return 0x60.chr
  when 'SndIns'; return 0x62.chr
  when 'SndGrp'; return 0x61.chr
  when 'SndX10'; return 0x63.chr
  when 'GetLnk'; return 0x69.chr
  when 'GetNext'; return 0x6A.chr
  when 'BtnRpt'; return 0x54.chr
  when 'GetCfg'; return 0x73.chr
  when 'StLnk'; return 0x64.chr
  when 'CancelLnk'; return 0x65.chr
  when 'MngLnk'; return 0x6F.chr 
  when 'RstPLM'; return 0x67.chr
  when 'SetCfg'; return 0x6B.chr
  when 'LEDON'; return 0x6D.chr
  when 'LEDOFF'; return 0x6E.chr
    ## hack
  when 'InsStdMsg'
    log('ERROR:PLMCommand encountered a COMMAND of INSSTDMSG')
    break
    return 0x62.chr
  end
end

def debug(text)
  work = 'OUT:'

  for c in 1..text.length
    work += padhex("%X" %text[c-1]) + ' '
  end
  log($green + work + "Length:" + text.length.to_s + $grey)
end

def debugin(text)
  work = 'IN:'

  for c in 1..text.length
    work += padhex("%X" %text[c-1]) + ' '
  end
  log($red + work + "Length:" + text.length.to_s + $grey)
end

def padhex(hex)
  if hex.length==1
    hex = "0" + hex
  end
  return hex
end

def percenttohex(level)
  # convert from percent to byte
  return "%X" %((level.to_i * 2.55)).to_i
end

def hextopercent(level)
  return ((level.hex.to_i / 2.55)).to_i
end

def log(line)
  $log = File.open("/var/log/pluto/" + device_.devid_.to_s + "_Generic_Serial_Device.log", "a")
  $log.puts "(***):" + line.to_s
  $log.close
end
def log2(line)
  #this will send a message out the the orbiters..
  #/usr/pluto/bin/MessageSend localhost 0 20 1 809 9 "Text to Display" 70 "alert" 182 "30" 251 "??"
  cmd = Command.new(device_.devid_, -1000, 1, 1, 809)
  cmd.params_[9] = line #text to display
  cmd.params_[70] = 'PLMMessage' #Token
  cmd.params_[182] = '10' #Timeout in seconds
  cmd.params_[251] = '??'
  SendCommand(cmd)
end
def checkChildRecordsinPLM()
  #  log('In CheckChildRecordsinPLM')
  # time to verify all children are in the PLM
  #
  #	log('Total PLM Records:' + $plmdatabase.nitems.to_s)
  #	$plmdatabase.each{|record|
  #		log('Record: = '+ getIIDfromRecord(record) + ' Group:' + getGroupfromRecord(record))
  #	}

  $childdatabases.each_key {|child|
    if existsinplm(child) == false
      #log(child + ' needs to be added to PLM')
      sendAddtoPLM(child)
    else
      log(child + ' exists in PLM')
    end
    @result = 'Child: ' + child + "\n"
    #now to scan the childs database
    for record in 1..($childdatabases[child].nitems - 1)
      @test = $childdatabases[child][record]
      if existsinplm(getIIDfromRecord(@test)) == false
        log(getIIDfromRecord(@test) + ' needs to be added to PLM')
        sendAddtoPLM(getIIDfromRecord(@test))
      else
        log(getIIDfromRecord(@test) + ' exists in PLM')
      end
      #Also check to see if it needs to be added in the childdatabases
      if existsinchild(getIIDfromRecord(@test)) == false
        log(getIIDfromRecord(@test) + ' needs to be added to the child database')
        addtochild(getIIDfromRecord(@test))
      end
    end
  }

end
def existsinplm(insteonid)
  result = false
  $plmdatabase.each{|record|
    #log(insteonid + '==' + getIIDfromRecord(record))
    if insteonid == getIIDfromRecord(record)
      #log('TRUE')
      result = true
    end
  }
  return result
end
def existsinchild(insteonid)
  result = false
  $childdatabases.each_key{|record|
    if insteonid == record
      result = true
    end
  }
  return result
end
def addtochild(insteonID)
  log('addtochild Routne called')
  log('Adding ' + insteonID + ' to the child database...')
  $childdatabases[insteonID] = ['****************']
  sendPing(insteonID)
  $rerun = true
end
def sendAddtoPLM(insteonID)
  log('Adding ' + insteonID + ' to the PLM database...')
  #This adds a record into the PLM
  @insID = insteonID.split('.')
  param = {'Command' => 'MngLnk',
    'Parameter1' => '40', #control code -- add new record as Controller
    'Parameter2' => 'C2', #All Link Record Flags AKA Record Control Byte
    'Parameter3' => '01', #All Link Group
    'Parameter4' => @insID[0], #HB
    'Parameter5' => @insID[1], #MB
    'Parameter6' => @insID[2], #LB
    'Parameter7' => '01', #Link Data 1 ON-Level
    'Parameter8' => '01', #Link Data 2 Ramp Rate
    'Parameter9' => 'FF'} #Link Data 3 not used
  if $wAIT == true
    $cmdqueue.insert(1, param)
  else
    $cmdqueue.insert(0, param)
  end

  SndIns()
end

def getIIDfromRecord(recordstring)
  #this extracts the insteonID string from the record.
  #log('getIIDfromRecord::recordstring:' + recordstring)
  @idhb = recordstring[4..5]
  @idmb = recordstring[6..7]
  @idlb = recordstring[8..9]
  @result = @idhb + '.' + @idmb + '.' +@idlb
  #log('GetIIDfromRecord: Found ID:' + @result)
  return @result
end

def processBroadcastMessage(param)
  #search the child databases for responders,
  #and fire events for each responder.
  #Message flag is in parameter9 Group command 0xCx (All-Link Broadcast Message Pg 42.)
  #Group is in parameter8
  #From InsteonID is parameters 3, 4, 5
  group = param['Parameter8']
  from = padhex(param['Parameter3']) + '.'
  from += padhex(param['Parameter4']) + '.'
  from += padhex(param['Parameter5'])
  log('Looking for ' + from + ' Group:' + group)
  #Ok, now have to search child databases for from AND group AND responder
  $childdatabases.each_key{|child|
    #log('Searching:' + child)
    for rec in 1..($childdatabases[child].nitems - 1)
      record = $childdatabases[child][rec]
      if getIIDfromRecord(record) == from # First, look for Insteon ID
        #log('Found ID')
        if getGroupfromRecord(record) == group #next, Group
          #log('Found Group')
          if isResponderRecord(record) # is a responder?
            #log('Found Responder')
            #figure out the child devicenum
            from = $children[child]
            #figure out the command
            case param['Parameter10'].hex
            when 0x11 #on
              reportStatus(from, 100)
            when 0x13 #off
              reportStatus(from, 0)
            when 0x17 #dim/brighten -ignore
              level = 0
            when 0x18 # STOP dim/brighten - sendgetstatus
              level = 0
              sendGetChildStatus(child)
            else
              level = 0
              log('Command is other than ON/OFF/Dim/Brighten')
            end
          end
        end
      end
      #log(record)
      #log(getIIDfromRecord(record))
      #log(getGroupfromRecord(record))
      #if isResponderRecord(record)
      #	log('Responder')
      #else
      #	log('Controller')
      #end
    end
  }
end

def reportStatus(from, level)
  #Bug found: when a devices state is OFF, it ignores the setlevel?


  log('Entered reportStatus:' + from.to_s + ', ' + level.to_s)
  #this routine sends both a cmd[192,193] and sets the STATE via cmd[184][76]
  #from is the deviceid and level is percentage
	
  #first, send 
  if level == 0 then
    #have to first send an ON cmd to be sure the off cmd gets processed
    cmd = Command.new(from, from, 1, 1, 192)
    $ignorecmdon = true
    SendCommand(cmd)
  else
    #have to first send an OFF cmd...
    cmd = Command.new(from, from, 1, 1, 193)
    $ignorecmdoff = true 
    SendCommand(cmd)
    $ignorecmdon = true
    cmd = Command.new(from, from, 1, 1, 192)
    SendCommand(cmd)
  end

  #now, send command for state
  cmd = Command.new(from, from, 1, 1, 184) #SetLevel
  cmd.params_[76] = level.to_s
  $ignoresetlevel = true # to stop infinate loop
  SendCommand(cmd)
  log('ReportStatus: device:' + from.to_s + ' Status:' + level.to_s)
  if level == 0 then
    #now send the OFF command
    cmd = Command.new(from, from, 1, 1, 193)
    $ignorecmdoff = true
    SendCommand(cmd)
  end
end

def isResponderRecord(recordstring)
  work = recordstring[0..1].hex
  if (work & 0x40) == 0x40 #check bit 6
    result = false #signifies Controller record
  else
    result = true #signifies Responder record
  end
  return result 
end

def getGroupfromRecord(recordstring)
  #this extracts the GROUP from the record.
  if recordstring == nil
    return '00'
  else
    return recordstring[2..3]
  end
end
def getdeltafromconfig(insteonID)
  #This returns the delta from the child.
  @work = $childdatabases[insteonID][0] # the settings stored in [0]
  if @work == nil
    return '00'
  else
    return @work[6..7]
  end
end
def sendGetChildStatus(insteonID)
  #log('sendGetChildStatus Called')
  @insID = insteonID.split('.')
  param = {'Command' => 'SndIns',
    'Parameter1' => @insID[0], 
    'Parameter2' => @insID[1],
    'Parameter3' => @insID[2],
    'Parameter4' => '0F', #flags
    'Parameter5' => '19', #Status Request
    'Parameter6' => '00'} #not used.
  $cmdqueue << param
  SndIns()
  #Returned response will have cmd1 = DBDelta
  #Returned response will have cmd2 = ON-Level
end


# time to define a structure to save the raw data in hex
# starts at [0]
#	Bytes	Meaning
#	0-1	Device Category
#	2-3	Device SubCategory
#	4-5	Device Firmware
#	6-7	Database Delta
#	8-9	reserved
#	10-11	reserved
#	12-13	reserved
#	14-15	reserved
###### First database record below (in same format its read from the device)
###### This is the same format as an ALL-Link Record Response from the PLM
###### (0x57) bytes 3..10
#	16-17	record control byte
#	18-19	Group
#	20-21	ID HB
#	22-23	ID MB
#	24-25	ID LB
#	26-27	Link Specific Data1
#	28-29	Link Specific Data2
#	30-31	Link Specific Data3
######
#	32-47  next database record...