User:Apagg: Difference between revisions
No edit summary |
No edit summary |
||
| (8 intermediate revisions by 2 users not shown) | |||
| Line 1: | Line 1: | ||
== Delayed event | [[Category:User Setups]] | ||
[[Category:Climate]] | |||
[[Category:Zwave_Setups]] | |||
= My Setup = | |||
== Home Automation == | |||
*[[Seluxit viaSENS Home Controller]] | |||
*[[LSControl ES 861]] Temperature sensor | |||
*[[LSControl ES 861 Humidity]] Humidity sensor ''(eats battery's)'' | |||
*[[Everspring ST814]] Temp/hum sensor | |||
*[[ACT Homepro ZDW230]] Dimmer wall mounted | |||
*[[Düwi 05433]] Dimmer wall mounted | |||
*[[ACT Homepro ZDP200]] Dimmer plugin | |||
*[[ACT Homepro ZRP200]] Appliance module plugin | |||
*[[Düwi plug adaptor switch ZW ZS 3500]] Appliance module plugin | |||
*[[Merten 507501]] Appliance module Flush-mounted | |||
*[[Express Controls EZmotion]] Temp/Light/Motion sensor | |||
*[[ACT Homepro ZTH200]] Remote | |||
*[[Tricklestar 200ZW-EU-W]] Remote | |||
= Delayed event = | |||
To make a scenario for heating my care in the morning and by a climate scenario on the orbiter I have made the following setup. | To make a scenario for heating my care in the morning and by a climate scenario on the orbiter I have made the following setup. | ||
This scenario turns on the wall outlet for the car and turns it off after 1,5 hours. If I execute this scenario form the orbiter it does not work it will just send all the commands at once and there will be no delay. So I hide this scenario by unchecking all the rooms. | This scenario turns on the wall outlet for the car and turns it off after 1,5 hours. If I execute this scenario form the [[orbiter]] it does not work it will just send all the commands at once and there will be no delay. So I hide this scenario by unchecking all the rooms. | ||
[[Image:varm bil (skjult).png|200px|]] | [[Image:varm bil (skjult).png|200px|]] | ||
I then made another scenario to execute this scenario: | I then made another [[scenario]] to execute this scenario: | ||
[[Image:varm bil.png|200px]] | [[Image:varm bil.png|200px]] | ||
I also added a | I also added a [[Timed Events|Timed Event]] to execute this scenario every weekday morning. | ||
[[Image:varm bil 2.png|200px]] | [[Image:varm bil 2.png|200px]] | ||
= Climate control = | |||
I have started my quest to control all heating in my house using LMCE. I am using | I have started my quest to control all heating in my house using LMCE. I am using [[Z-Wave]] as my primary control system. The temp sensors are [[LSControl ES 861]] and the heaters are controlled by various [[Z-Wave]] modules. | ||
The first room out is the bedroom. I only need to have this room warm when I go to bed and wake up. If I am not sleeping at home I don't need to turn the heat up at all (HouseMode = Extended-away). These two events control the heater. They are both Temperature Changed Events. The first event turns the heater on, the second turns it off. <br> | The first room out is the bedroom. I only need to have this room warm when I go to bed and wake up. If I am not sleeping at home I don't need to turn the heat up at all ([[Event_criteria#House_Mode|HouseMode]] = Extended-away). These two events control the heater. They are both Temperature Changed [[Events]]. The first event turns the heater on, the second turns it off. <br> | ||
[[Image:Sov on.png|200px]] [[Image:Sov off.png|200px]] | [[Image:Sov on.png|200px]] [[Image:Sov off.png|200px]] | ||
Latest revision as of 13:46, 18 August 2010
My Setup
Home Automation
- Seluxit viaSENS Home Controller
- LSControl ES 861 Temperature sensor
- LSControl ES 861 Humidity Humidity sensor (eats battery's)
- Everspring ST814 Temp/hum sensor
- ACT Homepro ZDW230 Dimmer wall mounted
- Düwi 05433 Dimmer wall mounted
- ACT Homepro ZDP200 Dimmer plugin
- ACT Homepro ZRP200 Appliance module plugin
- Düwi plug adaptor switch ZW ZS 3500 Appliance module plugin
- Merten 507501 Appliance module Flush-mounted
- Express Controls EZmotion Temp/Light/Motion sensor
- ACT Homepro ZTH200 Remote
- Tricklestar 200ZW-EU-W Remote
Delayed event
To make a scenario for heating my care in the morning and by a climate scenario on the orbiter I have made the following setup.
This scenario turns on the wall outlet for the car and turns it off after 1,5 hours. If I execute this scenario form the orbiter it does not work it will just send all the commands at once and there will be no delay. So I hide this scenario by unchecking all the rooms.
I then made another scenario to execute this scenario:
I also added a Timed Event to execute this scenario every weekday morning.
Climate control
I have started my quest to control all heating in my house using LMCE. I am using Z-Wave as my primary control system. The temp sensors are LSControl ES 861 and the heaters are controlled by various Z-Wave modules.
The first room out is the bedroom. I only need to have this room warm when I go to bed and wake up. If I am not sleeping at home I don't need to turn the heat up at all (HouseMode = Extended-away). These two events control the heater. They are both Temperature Changed Events. The first event turns the heater on, the second turns it off.