User:Apagg

From LinuxMCE
Revision as of 07:41, 1 April 2010 by Apagg (Talk | contribs)

Jump to: navigation, search

Delayed event

To make a scenario for heating my care in the morning and by a climate scenario on the orbiter I have made the following setup.


This scenario turns on the wall outlet for the car and turns it off after 1,5 hours. If I execute this scenario form the orbiter it does not work it will just send all the commands at once and there will be no delay. So I hide this scenario by unchecking all the rooms.

Varm bil (skjult).png

I then made another scenario to execute this scenario:

Varm bil.png

I also added a Timed Event to execute this scenario every weekday morning.

Varm bil 2.png

Climate control

I have started my quest to control all heating in my house using LMCE. I am using Z-Wave as my primary control system. The temp sensors are LSControl ES 861 and the heaters are controlled by various Z-Wave modules.

The first room out is the bedroom. I only need to have this room warm when I go to bed and wake up. If I am not sleeping at home I don't need to turn the heat up at all (HouseMode = Extended-away). These two events control the heater. They are both Temperature Changed Events. The first event turns the heater on, the second turns it off.
Sov on.png Sov off.png

Execute scenario from zwave switch

I am experimenting on using a zwave switch to execute scenarios.

  1. associate the zwave controller to a group off the switch using webadmin.
  2. Create a advanced "respond to event" to trigger by "state changed" and set PK_Device to the zwave controller and PK_Event Parameter > state to 255.
  3. edit the event commands